Graphite Electrode Manufacturers In Sinis HP500 pro Ferro faciens Arcum Electric Fornacis
Technical Parameter
Parameter | Pars | Unitas | HP 500mm(20") Data |
Nominal Diameter | Electrode | mm (inch) | 500 |
Max Diameter | mm | 511 | |
Min Diameter | mm | 505 | |
Longitudo nominal | mm | 1800/2400 | |
Max Longitudo | mm | 1900/2500 | |
Min Longitudo | mm | 1700/2300 | |
Current Density | KA/cm2 | 15-24 | |
Current Capacitas baiulans | A | 300000-48000 | |
Imprimis resistentia | Electrode | μΩm | 5.2-6.5 |
Papilla | 3.5-4.5 | ||
Flexurae Fortitudo | Electrode | Mpa | ≥11.0 |
Papilla | ≥22.0 | ||
Modulus | Electrode | Gpa | ≤12.0 |
Papilla | ≤15.0 | ||
mole Density | Electrode | g/cm*3 | 1.68-1.72 |
Papilla | 1.78-1.84 | ||
CTE | Electrode | 10-6/ | ≤2.0 |
Papilla | ≤1.8 | ||
Cinis Content | Electrode | % | ≤0.2 |
Papilla | ≤0.2 |
NOTE: Quaelibet specifica exigentia in dimensione offerri potest.
Late usus in Industry
- Arcus enim Electric fornax chalybea faciens
- Nam Yellow phosphoro fornace
- Applicare ad fornacem industrialem pii vel aeris liquefactionem.
- Applicare ad Refine ferrum in fornacibus trunci et in aliis processibus excoquendis
Quam eligere Idoneum Graphite Electrode
Cum ad electionem graphite electrode ius venit, plures causae sunt considerandae.
- Uno modo, qualis electrode critica est. Electrode qualitas summus structuram magis aequabilem habebit, id quod minus proclivior est ad fracturam et spallationem.
- Secundo, magnitudo electrodis eligenda est secundum aestimationem potestatis EAF, cum maioribus fornacibus electrodes ampliores requirunt.
- Tertio genus electrode eligendum est secundum gradus ferri, parametri operandi, et consilium fornacis. Exempli gratia, electrodus UHP (Ultra High Power) fornacibus sublimibus potentiae aptior est, cum HP (High Power) electrode fornacibus mediae potentiae aptus est.
Gufan Graphite Electrode Nominal Diameter et Longitudo
Nominal Diameter | Actualis Diameter | Longitudo nominal | tolerantia | |||
mm | inch * | Max(mm) | Min(mm) | mm | Inch | mm |
75 | 3 | 77 | 74 | 1000 | 40 | +50/-75 |
100 | 4 | 102 | 99 | 1200 | 48 | +50/-75 |
150 | 6 | 154 | 151 | 1600 | 60 | ±100 |
200 | 8 | 204 | 201 | 1600 | 60 | ±100 |
225 | 9 | 230 | 226 | 1600/180 | 60/72 | ±100 |
250 | 10 | 256 | 252 | 1600/180 | 60/72 | ±100 |
300 | 12 | 307 | 303 | 1600/180 | 60/72 | ±100 |
350 | 14 | 357 | 353 | 1600/180 | 60/72 | ±100 |
400 | 16 | 408 | 404 | 1600/180 | 60/72 | ±100 |
450 | 18 | 459 | 455 | 1800/2400 | LXXII/96 | ±100 |
500 | 20 | 510 | 506 | 1800/2400 | LXXII/96 | ±100 |
550 | 22 | 562 | 556 | 1800/2400 | LXXII/96 | ±100 |
600 | 24 | 613 | 607 | 2200/2700 | 88/106 | ±100 |
650 | 26 | 663 | 659 | 2200/2700 | 88/106 | ±100 |
700 | 28 | 714 | 710 | 2200/2700 | 88/106 | ±100 |
Superficies Quality Ruler
1. Defectus vel foramina non plus quam duae partes in superficie electrode graphite debent, et defectus vel foraminum magnitudinem datas in tabulis infra memoratis excedere non licet.
2. Vox transversa nulla in superficie electrodis est. Nam rima longitudinalis, longitudo non plus quam 5% graphitarum circumferentiae, latitudo intra 0.3-1.0mm range. Vox longitudinalis data infra 0.3mm data debet esse neglegenda
3. Latitudo eius maculae asperae (nigrae) areae in superficie graphite electrode non minus quam 1/10 graphitae circumferentiae electrodis esse debet, et longitudo maculae asperi (nigrae) areae super 1/3 longitudinis graphite electrodis non licet.
Superficies defectus Data pro Graphite Electrode Chart
Nominal Diameter | Defectus Data (mm) | ||
mm | inch * | Diameter(mm) | Profundum (mm) |
300-400 | 12-16 | 20-40 | 5-10 |
450-700 | 18-24 | 30-50 | 10-15 |